CHARACTERISTICSHADALAN
® PZG 9ZH is an alkali-resistant and multi-axial glass fibre tissue for renovating old substrates that are no longer stable. For bridging cracks in concrete floors and cement screeds, with a crack width of < 1 mm. Saves the expensive disposition of old floors and the costly crack renovation of minor settlement and shrinkage cracks. In conjunction with HADALAN
® EBG 13E and HADALAN
® EG145 13E as well as the special HADALAN
® FGM003 57M filler combination, quick and high-strength industry floor renovations can be carried out.
- Alkali-resistant
- Self-laying
- Can be cut with a hook knife
- Easy to process
- As system component in the HADALAN® FloorRepair system
- Low-stress
- Quick and easy to apply
- Layer thickness above 3 mm
- High crack-bridging
- High flexibility
- High mechanical strength
- High bending tensile strength
- Resilient after a short time
- Cost-efficient and time-saving
INGREDIENTSWoven glass fabric, acrylate
QUANTITY REQUIREDThe quantities required of the levelling compound vary depending on construction site conditions.
HADALAN® PZG 9ZH
HADALAN® EBG 13E with HADALAN® FGM003 57M at a mixing ratio of 1 : 2.35
Primer per application
Levelling compound 3 mm |
1.05 m2/m2
1/1 water diluted
150 g/m²
about 5.5 kg/m² (proportionately 1.65 kg -EBG 13E and
4 kg -FGM003 57M) |
PREPARATION OF THE SURFACEClean the substrate to be renovated. Remove all fats, residues of old adhesive and other separating dirt. Then vacuum-clean the surface thoroughly. Edge insulating strips (10 mm) must absolutely be installed. Cracks bigger than 1mm must be functionally connected. Holes, recesses and irregularities have to be closed beforehand. Depending on the substrate, we recommend renovating with HADALAN
® EBG 13E and HADALAN
® FGM003 57M or a mix with HADALAN
® FGM012 57M.
Prime the given surface with HADALAN
® EBG 13E (permitting diffusion) or HADALAN
® EG145 13E (not permitting diffusion). Highly absorbent substrates or substrates that must be protected from rising damp are primed twice. Once the surface can be walked on, HADALAN
® PZG 9ZH is laid on the surface and cut.
APPLICATIONLay HADALAN
® PZG 9ZH on the prepared primed substrate and cut. Execute joints with about 5cm overlap. The fresh primer serves as adhesive layer; the subsequent covering is applied into the fresh primer on the tissue.
Processing with bonding agent HADALAN
® EBG 13E (solution permitting diffusion)
HADALAN
® EBG 13E is mixed with HADALAN
® FGM003 57M to render a levelling compound. Here we recommend a mixing ratio of 8.5 kg HADALAN
® EBG 13E and 20 kg HADALAN
® FGM003 57M. To improve levelling, 0.5 L of water can be added to the putty.
The floor levelling putty is evenly applied now using the serrated blade Spezial and ventilated with a spiked roller. Depending on the construction site conditions, the drying time is at least 4 h. Then further constructing can be executed. Depending on the construction site conditions, it cannot be excluded that the tissue will stand out / show through. To create an even, homogeneous layer, the surface is ground in between or another levelling coating is applied as specified above. With HADALAN
® EBG 13E, coating intervals are of no importance.
Processing with bonding agent HADALAN
® EG 145 13E (high stress / damp-tight execution)
HADALAN
® EBG 13E is mixed with HADALAN
® FGM003 57M to be a levelling compound. Here we recommend a mixing ratio of 8.7 kg HADALAN
® EG145 13E and 20 kg HADALAN
® FGM003 57M.
The floor levelling putty is now evenly applied with a maximum layer thickness of 3mm. Depending on the construction site conditions, the drying time is at least 4 h. Then e.g. coating with HADALAN
® VS 12E, HADALAN
® VS-E 12E, HADALAN
® MBH 12E or any other covering is possible. Depending on the construction site conditions, it cannot be excluded that the tissue will stand out / show through. To create an even, homogeneous layer, the surface is ground in between or another levelling coating is applied as specified above. The coating compound must also be ground when the coating intervals cannot be observed. See the relevant codes of practice.
IMPORTANT NOTES- Install the sheets with an overlap of about 5 cm.
- Please observe the system product data sheets
SAFETY PROVISIONS/RECOMMENDATIONSNo special steps required
DISPOSALThe local waste removal regulations must be observed.